英格索兰 Ingersoll Rand (Joy/Cooper/Cameron) 空压机 MLM控制盘
2023-03-30
生产厂家:Ingersoll Rand(IR)/CAMERON
Ingersoll Rand(IR)/CAMERON ID:AAP3798102-00130
停产型号Other Part#:P3798102-00031, AAP37P3798102-00000,P37P3798102-00000
Ingersoll Rand/CAMERON MLM控制盘性能描述(或称:COOPER离心式空压机控制盘,控制板,控制器,MAIN LOGIC MODULE, MLM)
INPUT / OUTPUT MODULE SPECIFICATIONS
The IO module provides RTD inputs; analog inputs and outputs; and digital inputs and outputs. The IO module will communicate to the Control Module using a serial CANBus interface. Multiple IO modules can be dropped on the CANBus interface to allow IO expansion when required. Identical IO modules will be used for IO expansion.
Environmental:
- Operating temperature range: 32°F – 122°F (0 – 50°C) minimum rage
- Storage temperature range: -10°F to 140°F (-23 – 60°C) minimum range
- Max relative humidity: 92.5% non-condensing to 2000m altitude
- Ingress rating: NEMA 1 (to be mounted in NEMA12 to 4x enclosure)
- Power requirement: 24Vdc to control board; 100 – 240VAC to be supplied to panel
- UL / CSA / CE approvals
- Hazardous area purged panel applications
Module Power Requirements:
Voltage: 24VDC
Power: 50W
IO Module Inputs:
- – Analog inputs (qty 13)
- 4 – 20ma; 12- bit resolution; 0.5 % accuracy; channel common reference to controller common
- – Motor current analog input (qty 1)
- Current rating: 0 – 5A ac; Voltage rating: 0 – 30Vac max
- – On-board analog input for monitoring 24Vdc power supply (qty 1)
- – Temperature sensor inputs (qty 10)
- 3-wire RTD, 100 ohm PT; 12- bit resolution; 0.5 % accuracy
- – Analog outputs (qty 4)
- 4-20ma; 10 or 12 bit resolution
- – Digital inputs (qty 10)
- Dry contact; 24Vdc sinking; LED indicator on each channel
- – Digital outputs (24Vdc) (qty 11)
- Load rating: 1Adc per output, 6Adc max load all digital outputs
- Isolated / protected; LED indicator on each channel
- – Emergency stop dry contact input channel (qty 1)
- Failsafe interlocks: with motor output channel & emergency stop input
- Solid state motor 24Vdc control output
-
I/O Expansion Module:
- Up to 3 IO modules can be attached to the CANBus interface to allow additional IO expansion.
- Each IO module will have a unique CANBus ID number.
|
Weight: 5lbs (2.27Kg)
|
Dimensions: 17.5″ (44.5cm) H x 8″ (20.3cm) W x 3″ (7.6cm) D
|
Environment: Operating temperature range: 32F to 140F (0C to 60C).
|
Storage temperature range: -10F to 140F (-25C to 60C).
|
Maximum 95% relative humidity (non-condensing).
|
Power Requirements: 100-240VAC, 10 Amp, 50-60hz.
|
Power Fuse: 10 Amp, 250VAC, Type F
|
Power Buss: 100-240VAC, 10 Amp, 50-60hz.
|
Communications: C-Link Network Port (RS-485)
Modbus Port (RS-485)
MLM Communications Port, Supports 2-3 Modules.
|
Monitoring Inputs: (13) 4-20mA Current Loop Analog Inputs
(10) RTD Temperature Sensor Inputs
(8) 24VDC Digital Inputs
(1) 0 – 5 Amp Current Transducer Input
(1) 100 – 240VAC Digital Input (Optically Isolated
Solid State Relay 5 Amp Maximum Load)
|
Control Outputs: (4) 4-20mA Current Loop Analog Outputs
(12) 240VAC Digital Outputs (Solid-state relay, 5 Amp Maximum load)
|
Digital Output Fuse 5 Amp, 250VAC, Type F
|
Safety Approvals: (UL) Underwriters laboratories. USA and Mexico, Compliance with
applicable requirements of UL3111-1: 1994
CUL) Canadian Underwriters laboratories. Canada Compliance with
applicable requirements of CAN/CSA – C22.2 No. 1010.1-92
(CE) Marking for the European Union. Compliance with applicable
requirements of the EMC and Low Voltage directives.
|
|
技术支持:VANTAGE软件程序灌装,控制板故障判断。
|
技术支持:MU软件程序参数更改,压缩机运行故障判断。
|