Type | CSA120BC |
---|---|
Code | XCSA120BC |
INPUT TECHNICAL DATA | |
Input rated voltage | 12 Vdc |
Input voltage DC | 10.5…18 Vdc |
Current consumption | 10 A (12 Vdc) ±10% |
Inrush peak current | 60 A |
Internal protection fuse | T 20 A |
External protection on AC line | MT: C-25 A / Fuse: T-25 A |
OUTPUT TECHNICAL DATA | |
Output voltage range | 24 Vdc |
Output adjustable range | 22.5…27.5 Vdc |
Continuous current | 5 A (24 Vdc) |
Overload limiting | 6.5 A |
Short circuit peak current | 12 A for 300 ms |
Ripple @ nominal ratings | 100 mVpp |
Hold up time | 1 ms |
Status indication | LED “DC OK” |
Parallel connection | possible |
Redundant parallel connection | possible with external ORing diode |
GENERAL TECHNICAL DATA | |
Efficiency | 83% (12 Vdc) |
Dissipated power | 25 W (12 Vdc) |
Operating temperature range | –20…+50°C |
Input / output isolation | 2.1 kVdc / 60s |
Input / ground isolation | 1.41 kVdc / 60s |
Output / ground isolation | 0.75 kVdc / 60s |
Standard / approvals | EN 60950-1 |
EMC Standard | EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 |
Overvoltage category / pollution degree | II / 2 |
Protection degree | IP 20 |
Connection terminal | 2.5 mm² / 2.5 mm² |