PR Electronics Universal AC / DC transmitter PR 4179

2026-04-10

PR4179 Universal AC / DC transmitter

Input specifications

Current input

Signal range 0…5 AAC / 40…400 Hz
Maximum input limit 6.00 AAC @ 40°C
Programmable measurement ranges 0…0.5; 0…1; 0…2.5 & 0…5 AAC
Custom configurable signal range 0…5 AAC /40…400 Hz
Min. measurement range (span) 0.5 AAC
Input resistance < 0.042 Ω (incl. terminals)

Voltage input

Signal range 0…300 VAC / 40…400 Hz
Programmable measurement ranges 0…0.5, 0…1, 0…2.83, 0…5, 0…120, 0…230 & 0…300 VAC
Custom configurable signal range 0…300 VAC / 40…400 Hz
Min. measurement range (span) 0.5 VAC
Input resistance Nom. 3 MΩ || 100 pF

Output specifications

Active unipolar and bipolar mA output

Programmable ranges 0…20, 4…20 and S4…20 mA ±10 and ±20 mA
Direct or Inverted Action
Load (@ current output) ≤ 800 Ω
V-curve function, active signals, 100-0-100% 20-0-20 mA

Passive 2-wire mA output

Programmable ranges 0…20 and 4…20 mA Direct or Inverted action
V-curve function, 100-0-100% 20-0-20 mA
External loop supply 3.5…30 V

国内销售