Wenglor P1PC212 Laser Distance Sensor Triangulation

2026-03-17

Optical Data

Working Range 50 … 350 mm
Measuring Range 50 … 350 mm
Reproducibility maximum 300 µm
Reproducibility: 1 Sigma 30 µm
Linearity Deviation 600 µm
Switching Hysteresis  < 0.5 %
Light Source Laser (red)
Wavelength 655 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 18 … 30 V DC
Current Consumption (Ub = 24 V) < 35 mA
Switching Frequency 650 Hz
Measuring Rate 2,500 /s
Response Time  < 0.77 ms
Temperature Drift < 60 µm/K
Temperature Range -25 … 50 °C
Number of Switching Outputs 1
Switching Output Voltage Drop < 1.5 V
Switching Output/Switching Current 100 mA
Analog Output 0…10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
IO-Link transmission speed COM3
Protection Class III
FDA Accession Number 2512215-000

Mechanical Data

Setting Method Teach-In
NFC
Housing Material Plastic, ABS
Degree of Protection IP67
IP68
Connection M12 × 1; 5-pin
Optic Cover Plastic, PMMA
Weight 37 g

国内销售
International sales