Wenglor PNBC101 Laser Distance Sensor Triangulation

2026-03-17

Optical Data

Working Range 20 … 24 mm
Measuring Range 4 mm
Reproducibility maximum 4 µm
Reproducibility: 1 Sigma 0.3 µm
Linearity Deviation 2 µm
Light Source Laser (red)
Wavelength 658 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 2
Max. Ambient Light 10,000 Lux
Light Spot Diameter  < 0.15 mm
 
 
 
 
 

Electrical Data

Supply Voltage 15 … 30 V DC
Current Consumption (Ub = 24 V) 280 mA
Switching Frequency 15 kHz
Response Time  < 33 µs
Output rate 10 … 30,000 /s
Temperature Drift 0.2 µm/K
Temperature Range -10 … 40 °C
Number of Switching Outputs 4
Switching Output Voltage Drop < 1.5 V
Switching Output/Switching Current 100 mA
Analog Output 4…20 mA/0…10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Teach Mode VT, FT
Interface Ethernet TCP/IP; EtherCat
Transmission rate 100 Mbit/s
Protection Class III
FDA Accession Number 2320541-000

Mechanical Data

Setting Method Teach-In
Web server
Housing Material Aluminum, anodised
Degree of Protection IP67
Connection M12 × 1; 8-pin
Type of Connection Ethernet M12 × 1; 4-pin
Optic Cover Glass
Weight 385 g

国内销售
International sales